Customer Service

 

 

โฐ Monโ€“Fri
10:00 AM โ€“ 5:00 PM (EST)
โœ‰๏ธ support@switchprince.com
๐Ÿ“ Ships from the United States

KTE 303 E87438 Wiring Diagram

Wiring instructions for the KTE 303 (E87438), a 2 terminal on/off pull chain light switch for ceiling fan lights and lamps. It has two terminals and no wire leads.

Safety: turn off the electrical current at the source by turning off the circuit breaker. Skipping this step can cause electric shock, fire, serious injury or death.

Check your old switch first. This wiring guide is for a light switch where:

  • The switch has 2 terminals (no wire leads).
  • The function is on/off.

If your old switch has 3 wires, you need a 3-wire switch such as the Zing Ear ZE-110. The KTE 303 is also sold with 2 wire leads. That version connects the same way as the ZE-109 and ZE-109M. See all 2 wire light switches.

Switch this wiring guide covers

SwitchDetails
KTE 303 (E87438)2 terminals, on/off, 6A 125VAC / 6A 250VAC. View the KTE 303

KTE 303 2 terminal switch

KTE 303 2 terminal on/off pull chain light switch, 6A 125VAC / 3A 250VAC

How to wire the KTE 303

  1. Turn off the electrical current at the source by turning off the circuit breaker. Failure to disconnect power may cause fire, electric shock, serious injury or death.
  2. Take a photo of the old switch and note which wire is attached to each of its two terminals.
  3. Remove the wires from the old switch.
  4. Attach one wire from the fan to one terminal on the KTE 303 and the other wire to the other terminal. The terminals accept UL 1015 AWG#18 or UL 3321 AWG#18 wire.
  5. Make sure each wire is fully inserted and held firmly in its terminal. Wire connectors are not needed. Loose connections can cause fire, electric shock or serious injury.
  6. Turn the power back on and pull the chain to test the light.

Questions about the KTE 303

How do I wire the KTE 303?

Turn off the breaker, note which wire is on each terminal of the old switch, then insert one wire from the fan into each of the two terminals on the KTE 303, the same way as on the old switch. Make sure each wire is fully inserted and held firmly. Wire connectors are not needed.

Does it matter which wire goes on which terminal?

The KTE 303 is a 2 terminal on/off switch with no numbered terminals or speed positions. Insert one wire into each terminal, the same way your old switch was connected.

What wire does the KTE 303 accept?

The terminals accept UL 1015 AWG#18 or UL 3321 AWG#18 wire.

Can I use the KTE 303 to replace a 3-wire light switch?

No. If your old switch has 3 wires, you need a 3-wire switch such as the Zing Ear ZE-110.

What does E87438 mean on the KTE 303?

E87438 is the UL approval number listed for the KTE 303. The model number is 303.

Leave a Reply

Your email address will not be published. Required fields are marked *